Data Centres

Connaught are proud to be involved in new many new Data Centre installations both large and small.  We also regularly undertake work on existing raised floor systems.

Many of these cases are direct for the end user or for the client’s facilities management team. Below are some recent projects where the client or end user has requested the project specifics remain confidential.

West London Data Centre

Supply & Installation of 5,200 m2 Heavy grade vinyl bonded raised floor panels forming data halls, service corridors, support & offices areas , installation of plant bases , heavy duty floor grilles and associated works.
Attendance upon Mechanical, Electrical & Data Cabling, Services Sub-Contractors
Contract Duration – 10 months.

Nottingham Data Centre

Supply and installation of 1,250 m2 across new extra heavy grade vinyl bonded raised floor to form a new across two data hall’s, client workshops, build rooms and associated office support areas. Floors installed to 450mm, 600mm and 800mm.
Works included pre-marking of pedestal positions, floor sealers and forming of ramps and steps to changes in floor height plus hand and guardrails installed to all rooms.
Contract Duration – 4 weeks

M4 Corridor Data Centre

Supply and installation of 7,800 m2 new heavy grade vinyl bonded raised floor to form 3 new data halls and back of house / support areas.
Additional works included installation of CRAC Unit plenums, RPP frames and installation of epoxy floor paint to all areas.
Attendance upon Mechanical, Electrical & Data Cabling, Services Sub-Contractors
Contract Duration – 4 months.

Hertfordshire Data Centre

Removal of old bare faced raised floor panels and installation of new medium grade vinyl panels with ramp and door well vinyl areas.
Contract Duration – 1 week

East Coast Scottish Data Centre

Supply and installation of 2,900 m2 new extra heavy grade vinyl bonded raised floor to form a new data hall and associated office support areas.
Works included installation of a floor with a finished floor height of 1.3m with a Sub-Contractor design secondary subfloor installed at low level on the same pedestals to span across chilled water pipework.
Attendance upon Mechanical, Electrical & Data Cabling, Services Sub-Contractors
Contract Duration – 4 months.

Scottish County Council Data Centre

Supply and installation of 100 m2 new extra heavy grade vinyl bonded raised floor to form a new Comms Room including supply and installation of ramp with handrail.
Contract Duration – 1 week

Major Bank Data Centre

Attendance upon Mechanical, Electrical & Data Cabling, Services Sub-Contractors for refurbishment works to large data hall. Works included installation of replacement panels, heavy duty floor grilles and localised strengthening works for new equipment. Floor box cut outs supported and Koldlok cable management bush strip grommets installed.
Contract Duration – 1 month over 4 weekend shifts